All Products

Electrocardiograph 3 channel

Medical Devices || Electrocardiography 3 Channel

Sold By : https://whiteapron.in
In Stock

Price : 33600 /pc 60000 Discount: 44%

Including All Taxes

Confirmity to standards  :US FDA

Purpose  :ECG machine is primary equipment to record ECG signal with

 interpretation which is required for recording and analyzing the

 waveforms with software.

Number of channels :3

Number of ECGs which can be :20-49

 store in ECG Machine

 

ECG machine should have full screen preview  : YES

 of ECG report for quality assessment checks

 prior to print

Type of inbuilt screen  :LCD

Size of screen in inches  :5

ECG machine should have alphanumeric keyboard for patient data entry  :Virtual

Size of printing paper  :A4

Provision of battery :Yes

Battery capacity  :50 ECG or 1 hour of continous rhythm recording on single charge

Connectivity to ECG MachineWireless : LAN

Availability of latest interpretation software  :No

Wireless acquisition module with RF technology  :No

System should have the dedicated software to download the ECG form machine in PDF format  :No

Warranty in years  :3

Provision of trolley  :No

Material of Frame of trolley  :No Trolley Provided

Material of Top of trolley  :No Trolley Provided

Number of castors  :No Trolley Provided

Number of brakes for castors  :No Trolley Provided

Height of trolley in inch  :No Trolley Provided

Provision of railing for top shelf  :No Trolley Provided

Availability of suitable cable arm having holder:No Trolley Provided

for ECG cables when not in use

ECG Machine 12 leads with interpretation  :Not provided

Patient Cable  :Not provided

Chest Electrodes Adult (set of Six) :1

Chest Electrodes Paediatric (set of Six) :Not provided

Limb Electrodes :Not provided

Thermal paper for 500 patients  :1 SET

Power cable for charging  :No

Supplied with Clip electrode  :No

Availability of test report from govt/ NABL/ILAC accredited lab covering all parameters  :No

Copies of all test reports to be provided to buyer on demand at time of supplies   :NA ,Incasetest reports not availabble

Certificates

Confirmity to standards

US FDA

Certification number and date

CDG/QMS/11057

Confirmity to safety of electromagnetic compatibility

IEC-60601-1-2:2001 (or equivalent BIS)

Confirmity to safety standard

IS - 13450 / IEC60601-1-2005

Performance Parameters

Purpose

ECG machine is primary equipment to record ECG signal with interpretation which is required for recording and analyzing the waveforms with software.

Operating modes of ECG Machine

Automatic, Manual and Rhythm

ECG machine should have ECG lead annotation facility

Yes

Leads which is in ECG machine should be able to acquire simultaneously and interpret them

12

Number of channels

3

ECG machine should acquire lead ECG for both adult and paediatric patients

Yes

The ECG machine should have facility to show lead fail indication

Yes

The ECG machine should have facility to show lead reversal indication

Yes

The ECG machine should have facility to show the impedance to quality check of connection

Yes

Acquisition time for ECG Machine in sec

10 sec

Digital sampling rate for Pacemaker spike detection

40000 s/sec/channel

Recording of digital sampling for pacemaker

1000 s/sec/channel

ECG machine should have real time colour backlit display of ECG waveforms with signal qualify indication for each lead

Yes

ECG machine should have frequency filters

Artifact, AC and low and high pass frequency filters

Number of ECGs which can be store in ECG Machine

20-49

ECG machine should have full screen preview of ECG report for quality assessment checks prior to print

Yes

Type of inbuilt screen

LCD

Size of screen in inches

5

Display resolution of ECG machine in pixels

640 x 480

ECG machine should have interpretation facility of the amplitudes, duration and morphologies of ECG waveforms and associated rhythm for adult and pediatric patient

Yes

ECG machine should have alphanumeric keyboard for patient data entry

Virtual

Size of printing paper

A4

Resolution of digital array printer using thermal sensitive paper in ECG Machine in dpi

200 dpi x 500 dpi on 25 mm/sec speed

ECG machine report format

Report formats of 3x4; 6x2, Rhythm for up to selected leads, 12 lead extended measurement, 1 minute of continuous waveform data for 1 selected lead

Provision of battery

Yes

Battery capacity

50 ECG or 1 hour of continous rhythm recording on single charge

Connectivity to ECG Machine

Wireless LAN

Storage on external portable memories

USB support

The individual patient lead should be change without replacing the whole patient cable assembly

Yes

Noise level in dba

15

Weight of ECG Machine in Kg

2.25

Frequency in Hz

300

Availability of latest interpretation software

No

Wireless acquisition module with RF technology

No

System should have the dedicated software to download the ECG form machine in PDF format

No

Warranty in years

3

User and service manual of ECG Machine

Yes

Environmental Parameters

Operating temperature and humidity

temperature of 10-40 degree C and relative humidity of 15-90%

Trolley

Provision of trolley

No

Material of Frame of trolley

No Trolley Provided

Material of Top of trolley

No Trolley Provided

Number of castors

No Trolley Provided

Number of brakes for castors

No Trolley Provided

Height of trolley in inch

No Trolley Provided

Provision of railing for top shelf

No Trolley Provided

Availability of suitable cable arm having holder for ECG cables when not in use

No Trolley Provided

Power Supply

Power input

220-240 V AC, 50 Hz fitted with Indian plug

Length of power cable in meter

4

Resettable over current breaker shall be fitted for protection

Yes

Accessories

ECG Machine 12 leads with interpretation

Not provided

Patient Cable

Not provided

Chest Electrodes Adult (set of Six)

1

Chest Electrodes Paediatric (set of Six)

Not provided

Limb Electrodes

Not provided

Thermal paper for 500 patients

1 SET

Power cable for charging

No

Supplied with Clip electrode

No

Reports

Manufacturer shall be ISO certified

ISO 13485

ISO cetificationdeatils such as date and number

CDG/QMS/11057

Availability of test report from govt/ NABL/ILAC accredited lab covering all parameters

No

Test report number ,Incase test reports not availabble , put NA

NA

Test report date, Incase test reports not availabble , put NA

NA

Name of test lab ,Incase test reports not availabble , put NA

NA

Address of test lab ,Incase test reports not availabble , put NA

NA

Copies of all test reports to be provided to buyer on demand at time of supplies ,

NA ,Incase test reports not availabble

Tags

test

Product images are used for reference purpose only. Actual products may differ slightly in appearance and colour due to lighting during photo shooting or monitor’s display.

Call us on :

1800 3002 6585

Some text some message..

Copyrights @2019 All rights reserved

×