All Products

Anaesthesia Trolley

Medical Devices || Anaesthesia Trolley

Sold By : https://whiteapron.in
In Stock

Price : 3119200 /pc 4480000 Discount: 30%

Including All Taxes

24.anaesthesia Trolley :

Conformity to standards   : European CE

Certification of manufactures   : ISO 9001 & ISO 13485

Confirmity to medical :electrical safety standardsIEC60601-2-13 and BS EN 6060-1-1

Purpose of anesthesiaworkstation   :     Anesthetic machine in used to provide an accurate and continuous supply of medical gases mixed with an accurate concentration of anaesthetic vapour and deliver this to the patient at a safe  pressure  and flow.

Components of Anesthesia workstation     : Anesthesia machine , Inbuilt ventilator , vaporisor , Gasdelivery system , Multi para monitor

Type of mounting for the Anesthesia workstation :Trolley Mounting

Material used for Anesthesia workstation: rust-proof ABS plastic with metal reinforcements

Mode of integrated scavenging system with pressure relief valve: Passive

Minimum Battery backup for anesthesia workstation: 2 hour

Minimum Battery backup for Ventilator: 2 hour

Minimum Battery backup for monitor :2 hour

Facility of manual ventillation in case of electricity and battery failure :Yes

Facility of gas and agent delivery in case of electricity and battery failure :Yes

Patient monitor from same manufacturer :Yes

The anesthesia machine can be used safely up to 1000 gauss line: No

Should have Air/N?O interlock: Yes

Warranty in years3

Mode of gas mixing :Electronic

Type of hypoxic guard with automatic cutoff of N2O  :Mechanical

Vaporizer compatible to gases:  Sevoflurane ,Isoflurane ,Desflurane ,Halothane

Number of bains circuit (adult) supplied with workstation :10

Number of Jackson Rees circuit for pediatric patients supplied with workstation :10

Volume capacity of breathing system in liters :1.5

Available modes of operating ventilator :Manual/spont, volume controlled , pressure controlled , SIMV/PS

Ventilator should be capable to pressure support :Yes

Screen size of Ventilator monitor in inches :15

Ventilator should be able to ventilate with atmospheric air if total gas supply failure :No

Type of monitor :TFT

Size of monitor in inches: 15

Patient multipara monitor shall be able to display parameters: HR, SpO2, NIBP, ECG, Temp, Agent identification (MAC)

NMT to be displayed: No

Dual temperature to be displayed: Yes

BIS/ENTROPY to be displayed: No

Capnography to be displayed: Yes

EtCO2 to be displayed: Yes

IBP1 and IBP2 to be displayed: Yes

CO(cardiac output) to be displayed: No

System to be supplied with oxygen monitor: Yes

Provision for laryngscopes: Not Provided

Reusable patient circuits: 1

Reusable masks:2

SPO? sensor provided:1

NIBP cuff:1

Skin and nasopharyngeal temperature probe:1

ETCO2 sample lines:10

Reusable IBP interface cables:1

Disposable IBP transducers:10

BIS sensors:Not provided

Accessories for wall mounting:NA (If trolley mounting)

Standards

Conformity to standards

European CE

Certification date and number

G1171264187005 DATED 07/01/2018

Certification of manufactures

ISO 9001 & ISO 13485

ISO certification number and date

Q64187003 and 2017-12-22

Confirmity to medical electrical safety standards

IEC60601-2-13 and BS EN 6060-1-1

 

Performance Parameters

Purpose of anesthesia workstation

Anesthetic machine in used to provide an accurate and continuous supply of medical gases mixed with an accurate concentration of anaesthetic vapour and deliver this to the patient at a safe  pressure  and flow.

Components of Anesthesia workstation

Anesthesia machine , Inbuilt ventilator , vaporisor , Gas delivery system , Multi para monitor

Type of mounting for the Anesthesia workstation

Trolley Mounting

Material used for Anesthesia workstation

rust-proof ABS plastic with metal reinforcements

Mode of integrated scavenging system with pressure relief valve

Passive

Minimum Battery backup for anesthesia workstation

2 hour

Minimum Battery backup for Ventilator

2 hour

Minimum Battery backup for monitor

2 hour

Facility of manual ventillation in case of electricity and battery failure

Yes

Facility of gas and agent delivery in case of electricity and battery failure

Yes

All the components likes anesthesia machine, integrated ventilator, vaporizer from the same manufacturer

Yes

Patient monitor from same manufacturer

Yes

Workstation should have minimum of two drawers to keep accessories, good mobility, anti static caster wheels with locking facility & conveniently placed handles for easy movement of the machine

Yes

All software updates should be provided free of cost during Warranty period

Yes

The anesthesia machine can be used safely up to 1000 gauss line

No

Should have Air/N?O interlock

Yes

Inspiratory time in sec

0.2 to 3 sec

Expiratory time

0.5 to 6 sec

Flow rate in lpm

0.2 to 6 lpm

Pressure relief

05 to 75 cm H20

Warranty in years

3

 

Gas Delivery System

Availability of Pin index yokes for gases

Oxygen and Nitrous oxide

Availability of Separate Pin index yokes for gases

Oxygen , Nitrous oxide , Air

Availability of cascading type flow meters for O2, N2O and air

Yes

Mode of gas mixing

Electronic

Availability of rotameter control guards in anesthesia workstation

Yes

Availability of pressure gauges for cylinder and pipelines in anesthesia workstation

Yes

Availability of audible and visual oxygen failure alarms

Yes

Minimum emergency oxygen flow in liter per minute

35-70

Type of hypoxic guard with automatic cutoff of N2O

Mechanical

 

Vaporizer

Number of quick mount type vaporizer for easy interchangeability at a time

2

Number of selectable back bar

2

Facility of interlock for vaporizer

Yes

Volume percentage of delivery range

0 to 10

Minimum agent capacity for free volatile anesthetic agent in ml

225

Sensor connection shall be internal to prevent disconnection

Yes

Vaporizer compatible to gases

Sevoflurane,Isoflurane,Desflurane,Halothane

The vaporizer design should be maintenance free

Yes

Vaporizer calibration requirement

After every 5 years

 

Breathing System

Breathing system should have fresh gas de-coupled / compensation , closed circle absorber system

Yes

Range of pressure relief valve in mbar of breathing system

5 to 75

Number of steps in change over from spontaneous to bag ventilation

single step

Number of reusable autoclavable closed silicone circuit supplied

2 for adult and 2 for pediatric

Number of bains circuit (adult) supplied with workstation

10

Number of Jackson Rees circuit for pediatric patients supplied with workstation

10

Volume capacity of breathing system in liters

1.5

Breathing system should have leak and compliance test

Yes

 

Anesthesia Ventilator

Available modes of operating ventilator

Manual/spont, volume controlled , pressure controlled , SIMV/PS

Ventilator should be capable to pressure support

Yes

Integrated ventilator shall not require bellows to be change for adults and infants

Yes

Tidal volume of ventilator in ml

20 to 1400 ml

PEEP of ventilator in mbar

0 to 20 mbar

Breathing frequency in BPM

4 to 60 BPM

Inspiratory pause percentage of Ti

0-50%

Screen size of Ventilator monitor in inches

15

Integrated ventilator shall be able to provide facility to monitor ETCO2 , Automatic identification of agents

Yes

Ventilator should be able to ventilate with atmospheric air if total gas supply failure

No

 

Monitor

Type of monitor

TFT

Size of monitor in inches

15

Monitor should not require lengthy start up procedure or calibration for display of parameters

Yes

The graphical and numerical trend with split screen duration

24 hours

Patient multipara monitor shall be able to display parameters

HR, SpO2, NIBP, ECG, Temp, Agent identification (MAC)

NMT to be displayed

No

Dual temperature to be displayed

Yes

BIS/ENTROPY to be displayed

No

Capnography to be displayed

Yes

EtCO2 to be displayed

Yes

IBP1 and IBP2 to be displayed

Yes

CO(cardiac output) to be displayed

No

ECG monitoring with standard lead configuration, I,II,III, avL, avF&V filters so that it is protected against defibrillator, electro surgery potentials, arrhythmia analysis and ST segment analysis with trends

Yes

NIBP should be determine with oscillometric method, should read systolic, diastolic and mean arterial pressure and pulse rate

Yes

Pulse oximetery with sensors suitable for adults, pediatric& neonate

Yes

ETCO2 measurement should be by infra –red absorption technique, measuring mode should be side stream or main stream and response time should be less than 3 seconds

Yes

Monitor should be able to monitor and display all parameters in single screen

Yes

Make of monitor if monitor provided is not from the same OEM and if from same OEM put NA

NA

System to be supplied with oxygen monitor

Yes

Alarms

Number of alarms

10

Alarms shall be adjustable to high / low limits with audio and visual alarms

Yes

Power Supply

Length of main cable in meter with power socket of standard indian make to be provided

5

Power supply

220-240V AC, 50 Hz single phase

Additional Accessories

Transparent re-usable silicon face mask size 0,1, 2, 3, 4 & 5

2 each

Breathing bag 2 Litre & 500 ml

2 each

3/5 ECG lead

2

Nasopharyngeal/rectal and skinTemperatureprobes should be Provided

2

Re usable adult cuffs, reusable Paediatric cuff and sets of Disposables cuff for neonatal

2

ETCO2 line and adapters

15 each

Mox regulator with 3 meter high Pressure tubing

1

Provision for laryngscopes

Not Provided

Reusable patient circuits

1

Reusable masks

2

SPO? sensor provided

1

NIBP cuff

1

Skin and nasopharyngeal temperature probe

1

ETCO2 sample lines

10

Reusable IBP interface cables

1

Disposable IBP transducers

10

BIS sensors

Not provided

Accessories for wall mounting

NA (If trolley mounting)

 

 

 

Tags

test

Product images are used for reference purpose only. Actual products may differ slightly in appearance and colour due to lighting during photo shooting or monitor’s display.

Call us on :

1800 3002 6585

Some text some message..