Sold By : https://whiteapron.in
In Stock

Price : 5200.00 /pc 5999.00 Discount: 13%

Including All Taxes

COMPUTERSIED INTERFERNTIAL THREAPY UNIT  In the Interferential Theraphy, we make use of two medium frequency alternatively currents. These medium frequency currents are not indentical & may differ in frequency  up to 150 Hz. Two oscillator of medium  frequency are generated  & are cross wisely applied to the body by means of four electrode pads . [ ( CH1) & (CH2) ] Each channel with one pair of pads i.e. two No. of  pads. One oscillator has a fixed frequency of 4000 Hz the other can be ranged in the freq. between 3850 Hz.

 

Both oscillator interfere i.e. intersect inside the body resulting in a modulated signal as a carrier & low frequency part ( The difference in frequency) for the actual therapy.

In simple words, we can define the interferential therapy as when two medium frequency currents i.e. CH1 & CH2 intersects with each other , leading interference currents to be generated at the place.

 

For example, let us take two medium frequency current, Current in CH1 = 4000 Hz. & in CH2 = 3850 Hz. These two currents are applied to any part of the body ( or a tissue ) at the points where the current cross each other. The new Beat frequency current set up is amplified  which is been modulated i.e. AMF Amplified modulated medium frequency ) & the frequencies of the new current is called Interferential current which is 150 Hz) by varying the constant frequency of the first  it is  possible to producer a range of  beat frequencies deep in the patients tissue. Thus it is possible to create any desired frequency  rate in the carrier currents.

 

SAILENT FEATURES

 

]  User friendly can be easily operated .

]  Totally father touch

]  Digital 7 segment display for actual current indication for both the individual channels.

]  Direct beat frequency control and digital display easily available.

]  Totally computersied unit

]  Scan mode (Continous & other )

]  Light weight easily portable and serviceable.

]  SAFE START feature

]  45 PRE FIXED PROGRAMES

 

TECHNICAL SPECIFICATIONS

 

Operating Voltage         230 volts AC  supply 50 Hz, 5 AC current.

Output type                   100% Isolated

Medium frequency        4 KHz ,  2.5 KHz, TNS MODE

Output                           Two separate outputs CH-1 & CH-2

Output Current               0 to 50 MA

Output frequency            It can be varied by intensity control. CH-1 – 4000 Hz  - 3850 Hz depending on the beat    freq. on selection of scan. CH-2  - 4000 Hz [constant]

Display                          Interference frequency indicator by 3 digit Digital Seven Seg. Display.

Timer                             0 – 99 minutes can be varied

Scan patterns                 Rectangular, Trapezoidal, Triangular   

Therapy modes              4 Pole interferential therapy, 4 pole vector interferential therapy,

                                      2 pole interferential therapy.

 

STANDARD ACCESSORIES .

 

Main Cable                      1pc

Patinet cable                    1pc

Patinet electrode              2pair

Jelly bottle                       1pc

Unit carry bag                  1pc

Small belt                         2pc

Large belt                        2pc

Tags

PAIN RELIEF, JOINS PAIN, MUSCLE PAIN, KNEE PAIN , BACK PAIN

Product images are used for reference purpose only. Actual products may differ slightly in appearance and colour due to lighting during photo shooting or monitor’s display.